§ Lord Lofthouse of Pontefractasked Her Majesty's Government:
What was the total amount of coal burnt at coal-fired generation plants with flue gas desulphurisation (FGD) equipment in each year between 1997 and 2002 compared with the amount at plants without FGD; and [HL1783]
What was the total amount of sulphur dioxide emissions from coal-fired generation plants with flue gas desulphurisation (FGD) equipment in each year
Statistics for UK coal-fired plant 1997 to 2000 with and without flue gas desulphurisation (FGD) equipment Year1 Question Unit 1997 1998 1999 2000 Total amount of coal burnt with FGD 000s tonnes 12,298 12,838 11,396 11,540 Total amount of coal burnt without FGD 000s tonnes 33,025 33,789 28,187 38,565 Total amount of SO2 emitted with FGD 000s tonnes 50 135 54 45 Total amount of SO2 emitted without FGD 000s tonnes 941 922 704 756 Average amount of SO2 emitted per gigawatt generated with FGD 000s of tonnes per GWh —3 4.092 1.79 1.48 Average amount of SO2 emitted per gigawatt generated without FGD 000s of tonnes per GWh —3 10.77 9.79 8.74 1 Data for 2001 and 2002 not yet available. 2 The FGD plant at AES Drax was out of commission for much of the year. 3 Data not available.