HC Deb 13 December 1994 vol 251 cc562-3W
Mr. Ainger

To ask the Secretary of State for the Environment if he will list those large combustion plants which emit nickel and vanadium, the fuel they burn, the total annual emissions permitted for each plant of nickel and vanadium, the actual total annual emissions of nickel and vanadium for each plant in the last three years and the maximum emission rate of nickel and vanadium for each plant.

Mr. Atkins

[holding answer Thursday 8 December 1994]: All large combustion plants burning oil, coal or orimulsion will release vanadium or nickel. The table provides as much information as the inspectorate has been able to assemble without disproportionate expense. This information covers 1993.

Vanadium release to air Nickel release to air
Site Fuel Maximum Rate (mgm/m3) Annual Permission (tonnes) Annual Actual (tonnes)2 Maximum Rate (mm/m3 Annual Permission (tonnes) Annual Actual (tonnes)2
National Power Pembroke HFO (Heavy Fuel Oil) 0.21 1 14 0.042 1 3
National Power Aberthaw A Coal and HFO 0.583 1 7.5 0.378 1 5
National Power Aberthaw B Coal and HFO 0.378 1 7.5 0.185 1 5
National Power Uskmouth Coal and HFO 0.22 1 0.16 0.14 1 0.10
National Power West Burton Coal 0.15 1 12.3 0.14 1 8.2
National Power Blyth A Coal 0.64 1 392 1
National Power Blyth B Coal 0.229 1 0.14 1
National Power Eggborough Coal 0.22 1 0.14 1
National Power Drax Coal 0.22 1 0.14 1
National Power Skelton Grange Coal 0.604 1 0.392 1
Powergen Ince Orimulsion or 27 (1993)
HFO 160 75 (1994) 1
Powergen Ratcliffe-on-Soar3 Coal 0.4 1 1 0.019 1 0.45
Powergen Drakelow Coal and HFO 1 1
National Power Rugeley A & B Coal and HFO 0.22 1 0.14 1
National Power Willington Coal and HFO 0.6 1 0.39 1
National Power Ironbridge Coal and HFO 0.22 1 0.14 1
Powergen Richborough Orimulsion 40 6.17 1 0.81
Powergen Grain HFO 1 less than 50 1 less than 11
National Power Littlebrook HFO 1 less than 348 1 less than 79
Powergen Kingsnorth Coal 1 less than 26 1 less than 31
National Power Fawley HFO 3 1 1
National Power Didcot Coal and HFO 0.22 1 0.14 1
1 No limit specified in the authorisation document.
2 Annual actual releases have been calculated from information in the application together with 1993-94 operating data. These figures are believed to be reasonably representative of releases for 1993. There is little information available for the last three years.
3 This power station has limits of 0.435 for vanadium and 0.175 for nickel with respect to releases to water.